/* ============================================================
   首页 A 方案 · 业务快查高视觉层（2026-11-06）
   - 独立增量文件，仅 index.html 引入；不修改 main.css / redesign.css
   - 前缀 ha- 隔离，避免与既有组件冲突
   - 原则：不删除任何原有 DOM、文字、内链、H1/H2、结构化数据
   重复展示面统一用原生 <details> 折叠（内容仍在 DOM，SEO 无损）
   ============================================================ */
:root{
  --ha-brand:#0a4d8c;
  --ha-deep:#0b1a2b;
  --ha-accent:#f5a524;
  --ha-ink:#0b1a2b;
  --ha-muted:#566b80;
  --ha-line:#e4ebf3;
  --ha-soft:#f6f8fc;
  --ha-r:14px;
  --ha-ease:cubic-bezier(.22,1,.36,1);
}
.ha-quick{background:#fff;padding:clamp(26px,3vw,42px) 0;border-bottom:1px solid var(--ha-line);}
.ha-quick *,.ha-quick *::before,.ha-quick *::after{box-sizing:border-box;}

/* ---------- 区块头 ---------- */
.ha-head{max-width:820px;margin-bottom:clamp(18px,2.2vw,26px);}
.ha-eyebrow{display:inline-flex;align-items:center;gap:8px;font-size:11.5px;font-weight:700;letter-spacing:.16em;color:var(--ha-brand);margin-bottom:9px;}
.ha-eyebrow::before{content:"";width:22px;height:2px;border-radius:2px;background:var(--ha-accent);}
.ha-title{font-size:clamp(21px,2.4vw,30px);line-height:1.28;font-weight:800;letter-spacing:-.012em;color:var(--ha-ink);margin:0 0 9px;}
.ha-sub{font-size:clamp(13px,1.2vw,14.5px);line-height:1.75;color:var(--ha-muted);margin:0;}
.ha-head-cta{display:flex;flex-wrap:wrap;gap:10px;margin-top:16px;}

/* ---------- 按钮 ---------- */
.ha-btn{display:inline-flex;align-items:center;justify-content:center;gap:6px;min-height:40px;padding:9px 18px;border-radius:10px;border:1px solid transparent;font-size:13.5px;font-weight:700;text-decoration:none;white-space:nowrap;transition:transform .2s var(--ha-ease),box-shadow .2s var(--ha-ease),background .2s,border-color .2s;}
.ha-btn-primary{background:var(--ha-brand);color:#fff;box-shadow:0 8px 20px rgba(10,77,140,.2);}
.ha-btn-primary:hover{transform:translateY(-2px);background:#083c6e;box-shadow:0 12px 26px rgba(10,77,140,.3);color:#fff;}
.ha-btn-ghost{background:#eef6fd;border-color:#b9d7f0;color:var(--ha-brand);}
.ha-btn-ghost:hover{background:var(--ha-brand);border-color:var(--ha-brand);color:#fff;}
.ha-btn-tel{background:#fff;border-color:#c9d8e8;color:var(--ha-brand);}
.ha-btn-tel:hover{border-color:var(--ha-brand);color:var(--ha-brand);}
.ha-btn:focus-visible{outline:2px solid var(--ha-brand);outline-offset:3px;}

/* ---------- 4 张主业务大卡（高视觉） ---------- */
.ha-grid{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:clamp(10px,1.4vw,16px);}
.ha-card{position:relative;display:flex;flex-direction:column;background:#fff;border:1px solid var(--ha-line);border-radius:var(--ha-r);overflow:hidden;transition:transform .24s var(--ha-ease),box-shadow .24s var(--ha-ease),border-color .24s;}
.ha-card:hover{transform:translateY(-4px);border-color:rgba(10,77,140,.35);box-shadow:0 14px 34px rgba(15,27,45,.13);}
.ha-card-media{position:relative;display:block;height:clamp(140px,15vw,190px);overflow:hidden;background:var(--ha-deep);}
.ha-card-media img{width:100%;height:100%;object-fit:cover;display:block;transition:transform .5s var(--ha-ease);}
.ha-card:hover .ha-card-media img{transform:scale(1.06);}
.ha-card-veil{position:absolute;inset:0;background:linear-gradient(180deg,rgba(11,26,43,.05) 0%,rgba(11,26,43,.12) 45%,rgba(11,26,43,.78) 100%);}
.ha-card-tag{position:absolute;top:10px;left:10px;padding:4px 9px;border-radius:999px;background:rgba(255,255,255,.94);color:var(--ha-brand);font-size:11px;font-weight:700;letter-spacing:.02em;}
.ha-card-name{position:absolute;left:14px;right:14px;bottom:12px;color:#fff;font-size:clamp(14px,1.35vw,17px);font-weight:700;line-height:1.35;text-shadow:0 1px 8px rgba(0,0,0,.4);}
.ha-card-body{padding:13px 14px 14px;display:flex;flex-direction:column;flex:1;}
.ha-card-body p{margin:0 0 12px;font-size:12.5px;line-height:1.6;color:var(--ha-muted);flex:1;}
.ha-card-cta{display:flex;align-items:center;gap:8px;}
.ha-book{flex:1;display:inline-flex;align-items:center;justify-content:center;min-height:34px;padding:7px 10px;border-radius:8px;background:var(--ha-brand);color:#fff;font-size:12.5px;font-weight:700;text-decoration:none;transition:background .2s;}
.ha-book:hover{background:#083c6e;color:#fff;}
.ha-more{display:inline-flex;align-items:center;min-height:34px;padding:7px 4px;color:var(--ha-brand);font-size:12px;font-weight:700;text-decoration:none;white-space:nowrap;}
.ha-more:hover{text-decoration:underline;}

/* ---------- 5 项专项服务（紧凑） ---------- */
.ha-mini-head{display:flex;align-items:baseline;gap:12px;margin:clamp(20px,2.4vw,28px) 0 11px;font-size:14px;font-weight:700;color:var(--ha-ink);}
.ha-mini-head a{font-size:12.5px;font-weight:600;color:var(--ha-brand);text-decoration:none;}
.ha-mini-head a:hover{text-decoration:underline;}
.ha-mini-grid{display:grid;grid-template-columns:repeat(5,minmax(0,1fr));gap:clamp(8px,1.2vw,14px);}
.ha-mini{display:flex;align-items:center;gap:10px;padding:11px 12px;border:1px solid var(--ha-line);border-radius:10px;background:var(--ha-soft);text-decoration:none;transition:border-color .2s,background .2s,transform .2s var(--ha-ease);}
.ha-mini:hover{border-color:var(--ha-brand);background:#fff;transform:translateY(-2px);}
.ha-mini img{width:44px;height:44px;border-radius:8px;object-fit:cover;flex:0 0 auto;}
.ha-mini b{display:block;font-size:12.5px;line-height:1.4;color:var(--ha-ink);}
.ha-mini i{display:block;font-size:11px;font-style:normal;color:var(--ha-muted);margin-top:2px;}

/* ---------- 品牌快查 ---------- */
.ha-brand{margin-top:clamp(20px,2.4vw,28px);padding:16px 18px;border:1px solid var(--ha-line);border-radius:var(--ha-r);background:var(--ha-soft);}
.ha-brand-head{display:flex;flex-wrap:wrap;align-items:baseline;gap:8px 12px;margin-bottom:12px;}
.ha-brand-head b{font-size:14.5px;color:var(--ha-ink);}
.ha-brand-head span{font-size:12px;color:var(--ha-muted);}
.ha-brand-head a{margin-left:auto;font-size:12.5px;font-weight:700;color:var(--ha-brand);text-decoration:none;}
.ha-brand-head a:hover{text-decoration:underline;}
.ha-chips{display:flex;flex-wrap:wrap;gap:7px;}
.ha-chip{display:inline-flex;align-items:center;gap:5px;padding:6px 11px;border:1px solid #d7e3f0;border-radius:999px;background:#fff;color:var(--ha-ink);font-size:12px;font-weight:600;text-decoration:none;transition:border-color .18s,background .18s,color .18s;}
.ha-chip i{font-style:normal;font-size:10.5px;color:#8a9bb0;font-weight:400;}
.ha-chip:hover{border-color:var(--ha-brand);background:var(--ha-brand);color:#fff;}
.ha-chip:hover i{color:rgba(255,255,255,.75);}

/* ---------- 信任数据条 ---------- */
.ha-trust{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:clamp(8px,1.2vw,14px);margin-top:clamp(18px,2.2vw,26px);}
.ha-stat{padding:14px 12px;border-radius:10px;background:var(--ha-soft);text-align:center;}
.ha-stat b{display:block;font-size:clamp(20px,2.2vw,27px);font-weight:800;line-height:1.2;color:var(--ha-brand);letter-spacing:-.02em;}
.ha-stat b i{font-size:13px;font-style:normal;font-weight:700;margin-left:2px;}
.ha-stat span{display:block;margin-top:5px;font-size:11.5px;line-height:1.5;color:var(--ha-muted);}

/* ---------- 服务场景 ---------- */
.ha-scene{display:flex;flex-wrap:wrap;align-items:center;gap:8px;margin-top:14px;}
.ha-scene-label{font-size:12px;font-weight:700;color:var(--ha-muted);margin-right:2px;}
.ha-scene a{padding:5px 11px;border-radius:999px;border:1px solid var(--ha-line);background:#fff;font-size:11.5px;color:var(--ha-ink);text-decoration:none;transition:border-color .18s,color .18s;}
.ha-scene a:hover{border-color:var(--ha-brand);color:var(--ha-brand);}

/* ---------- 底部转化条 ---------- */
.ha-cta{display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:16px;margin-top:clamp(20px,2.4vw,28px);padding:clamp(16px,2vw,22px);border-radius:var(--ha-r);background:var(--ha-deep);}
.ha-cta-copy{flex:1 1 380px;min-width:0;}
.ha-cta-copy b{display:block;font-size:clamp(15px,1.5vw,18px);font-weight:700;color:#fff;line-height:1.4;}
.ha-cta-copy span{display:block;margin-top:5px;font-size:12.5px;line-height:1.65;color:rgba(255,255,255,.72);}
.ha-cta-act{display:flex;flex-wrap:wrap;gap:10px;}

/* ---------- 折叠重复面（原生 details，内容始终在 DOM） ---------- */
.ha-fold{margin:0;border:1px solid var(--ha-line);border-left:4px solid var(--ha-brand);border-radius:12px;background:#fff;}
.ha-fold>summary{display:flex;flex-wrap:wrap;align-items:center;gap:8px 16px;padding:14px 20px;cursor:pointer;list-style:none;text-align:left;transition:background .2s;}
.ha-fold>summary::-webkit-details-marker{display:none;}
.ha-fold>summary:hover{background:#f7fbff;}
.ha-fold>summary:focus-visible{outline:2px solid var(--ha-brand);outline-offset:3px;}
.ha-fold-t{font-size:clamp(15px,1.6vw,18px);font-weight:700;color:var(--ha-ink);}
.ha-fold-s{font-size:12.5px;color:var(--ha-muted);flex:1 1 240px;}
.ha-fold-hint{margin-left:auto;padding:5px 12px;border-radius:999px;background:#eef6fd;color:var(--ha-brand);font-size:12px;font-weight:700;white-space:nowrap;}
.ha-fold[open]>summary{border-bottom:1px solid var(--ha-line);}
.ha-fold[open]>summary .ha-fold-hint{background:var(--ha-brand);color:#fff;}
.ha-fold-body{padding:4px 0 0;}
/* 折叠区内原有动画元素展开即显示，避免 IntersectionObserver 只算首屏导致空白 */
.ha-fold[open] .reveal,.ha-fold[open] [data-stagger]>*{opacity:1 !important;transform:none !important;visibility:visible !important;}
/* 把被折叠的 section 自身留白收紧，只保留折叠条 */
.page-home .ha-fold-sec{padding-top:clamp(14px,1.8vw,22px) !important;padding-bottom:clamp(14px,1.8vw,22px) !important;}
/* 折叠条与相邻标题区间距 */
.ha-fold + .ha-fold{margin-top:12px;}

/* ---------- 响应式：手机端显著变短 ---------- */
@media (max-width:1000px){
  .ha-grid{grid-template-columns:repeat(2,minmax(0,1fr));}
  .ha-mini-grid{grid-template-columns:repeat(3,minmax(0,1fr));}
}
@media (max-width:720px){
  .ha-quick{padding:24px 0;}
  .ha-grid{gap:10px;}
  .ha-card-media{height:132px;}
  .ha-card-name{font-size:13.5px;left:11px;right:11px;bottom:10px;}
  .ha-card-tag{top:8px;left:8px;font-size:10px;padding:3px 7px;}
  .ha-card-body{padding:10px 11px 11px;}
  .ha-card-body p{font-size:11.5px;margin-bottom:9px;line-height:1.5;}
  .ha-book{min-height:31px;font-size:11.5px;padding:6px 8px;}
  .ha-more{font-size:11px;min-height:31px;}
  .ha-mini-grid{grid-template-columns:repeat(2,minmax(0,1fr));gap:8px;}
  .ha-mini{padding:9px 10px;gap:8px;}
  .ha-mini img{width:36px;height:36px;}
  .ha-mini b{font-size:11.5px;}
  .ha-mini i{font-size:10.5px;}
  .ha-trust{grid-template-columns:repeat(2,minmax(0,1fr));gap:8px;}
  .ha-stat{padding:11px 8px;}
  .ha-stat b{font-size:21px;}
  .ha-stat span{font-size:11px;}
  .ha-brand{padding:13px 14px;}
  .ha-brand-head a{margin-left:0;}
  .ha-chip{padding:5px 9px;font-size:11.5px;}
  .ha-chip i{display:none;}
  .ha-head-cta .ha-btn{flex:1 1 auto;}
  .ha-cta{flex-direction:column;align-items:stretch;}
  .ha-cta-copy{flex:0 0 auto;}
  .ha-cta-act{width:100%;}
  .ha-cta-act .ha-btn{flex:1 1 auto;}
  .ha-fold>summary{padding:12px 14px;}
  .ha-fold-hint{margin-left:0;}
}
@media (max-width:389px){
  .ha-grid{grid-template-columns:1fr;}
  .ha-card-media{height:150px;}
  .ha-card-cta{flex-wrap:wrap;}
}
@media (prefers-reduced-motion:reduce){
  .ha-card,.ha-card-media img,.ha-mini,.ha-btn{transition:none;}
  .ha-card:hover,.ha-mini:hover,.ha-btn:hover{transform:none;}
}
